Generator and EPSS, 500 kW
Harbor Medical, central plant yard
- Fuel
- Diesel, paired with ATS-1
- Monthly run tests
- 9 of 12 this year
Commercial electrical
Keep recurring inspections, failed tests and the repair quotes that follow them connected. A transfer switch fails its monthly test, the failure stays on the switch, and a priced repair quote goes out the next day.
Panels, generators, transfer switches, emergency lighting, EV chargers and UPS systems each get a record with asset class, attributes and full test history.
Each record carries its test history and its paired equipment, and a failed test stays on it until the correction is done.
Generator and EPSS, 500 kW
Harbor Medical, central plant yard
Automatic transfer switch, 800 A
Main electrical room
Electrical maintenance is recurring work. One agreement plan bundles the recurring electrical cadences into a single contract, from generator run tests to the arc-flash study review. The cadences below are an example; the codes and standards your jurisdiction adopts set the actual intervals.
Panels, switchgear and switchboards, generators and EPSS, transfer switches, EV chargers and UPS and battery systems.
Eleven templates cover panel thermography, arc-flash re-study, generator run and load-bank tests, emergency-lighting tests and EV charger inspections.
Each visit runs against the system’s own cadence, with the last test’s results attached.
Harbor Medical, Full EPM Bundle
Electrical PM · 3 sites
Each row opens its own work orders from this agreement, each against its inspection template.
A failed item, such as a thermal anomaly or a transfer that does not complete, becomes a deficiency, and a Good, Better, Best quote is built from the open ones.
Inspection visits and repair work share one dispatch board, one set of service agreements and one invoicing run.
Statuses are current as of November 2026.
Equipment types, the eleven inspection templates, the agreement plan, turning electrical on yourself, failed-test-to-quote and license checks at dispatch by equipment work today. Certification rules by job type work too; a rule for one kind of visit, such as a thermography scan, is not available yet.
Panels, switchgear, switchboards and MCCs; generators and EPSS; automatic transfer switches; EV chargers; and UPS and battery systems. The eleven templates cover panel thermography, arc-flash re-study, generator run and load-bank tests, emergency-lighting tests and EV charger inspections.
Yes, once electrical is turned on. Dispatch checks the technician’s recorded license against the equipment: a state electrical license or NETA certification for panel work, and a state electrical license for generator and transfer-switch work. If the technician lacks it, the dispatcher gets a warning, or the assignment is blocked if your company sets it to. An override needs a reason. Owners can also require a certification by job type (install, maintenance, repair or inspection), optionally narrowed by equipment type or jurisdiction, in Settings, Compliance policy. A rule for one kind of visit, such as a thermography scan or an arc-flash re-study, is not available yet.
No. Thermal tracks the incident-energy study, its review date and the label attributes so you have the record. NFPA 70E, where adopted, calls for the study to be reviewed at least every five years; the study itself is done and signed by your licensed engineer.
An owner switches it on in Settings, Capabilities. It adds the inspection templates and the agreement plan. Turning it off blocks starting new inspections from those templates.
Yes. Inspection visits and repairs share the dispatch board, service agreements and invoicing with the rest of the operation.